Instrument configurations
There are number of UVI Instrument Configuration (IC)
modes defined for different types of science observations or
analyses. These configuration modes are basically an ordered
sequence of filter selections. When they are combined with Gain
and Loop counters, they can be used to define the UVI
Observation Sequence. The following table lists the Instrument
Configuration modes defined:
The following abbreviations are used
in the table:
|
04 |
1304 Filter |
|
56 |
1356 Filter |
|
LS |
LBH Short |
|
LL |
LBH Long |
|
SO |
Solar Filter |
|
S |
Shutter (Background) |
|
H |
Home (Background) |
|
DB |
Dynamic Balancing |
|
NM |
Normal Mode |
|
FM |
Fast Mode |
(NOTE: The Instrument Configuration number (IC)
may be used in the UVI query database where -X in the IC number
is the gain setting )
|
Instrument Configuration |
Description |
Number of Frames & Filters |
Minutes Per Cycle |
|
1-1-1-X |
Fixed Filter: "1304", Special Request |
1,04 - 1,H - 1,04 - 1,H - 1,04 - 1,H |
7.36 |
|
1-1-2-X |
Fixed Filter: "1304" |
2,04 - 2,04 - 2,04 - 2,04 - 2,04 - 2,S |
7.36 |
|
1-2-2-X |
Fixed Filter: "1356" |
2,56 - 2,56 - 2,56 - 2,56 - 2,56 - 2,S |
7.36 |
|
1-3-2-X |
Fixed Filter: "LBH Short" |
2,LS - 2,LS - 2,LS - 2,LS - 2,LS - 2,S |
7.36 |
|
1-4-2-X |
Fixed Filter: "LBH Long" |
2,LL - 2,LL - 2,LL - 2,LL - 2,LL - 2,S |
7.36 |
|
1-5-2-X |
Fixed Filter: "Solar" |
2,SO - 2,SO - 2,SO - 2,SO - 2,SO - 2,S |
7.36 |
|
2-1-1-X |
Cycling 2 Filters: "LBH Short & LBH
Long", 1 Frames |
1,LS - 1,LL - 1,LS - 1,S |
2.45 |
|
2-1-2-X |
Cycling 2 Filters: "LBH Short & LBH
Long", 2 Frames |
2,LS - 2,LL - 2,LS - 2,S |
4.90 |
|
2-1-3-X |
Cycling 2 Filters: "LBH Short & LBH
Long", 2 Frames, 1 BKG |
2,LL - 2,LS - 1,S |
3.06 |
|
2-1-4-X |
Cycling 2 Filters: "LBH Short & LBH
Long", 1 Frames, 1 BKG |
1,LL - 1,LS - 1,S |
1.84 |
|
2-1-5-X |
Cycling 2 Filters: "LBH Short & LBH
Long", 1 Frames |
1,LL - 1,LS |
1.22 |
|
2-1-6-X |
Cycling 2 Filters: "LBH Short & LBH
Long", 2 Frames |
2,LL - 2,LS |
2.45 |
|
2-2-2-X |
Cycling 2 Filters: "1356 & 1304",
2 Frames |
2,56 - 2,04 - 2,S |
3.07 |
|
2-2-8-X |
Cycling 2 Filters: "1356 & 1304",
8 Frames |
4,56 - 4,56 - 4,04 - 4,04 - 2,S |
11.04 |
|
3-1-2-X |
Cycling 3 Filters: "LBH Long, 1356, &
1304", 2 Frames |
2,04 - 2,56 - 2,LL - 2,S |
4.90 |
|
3-2-2-X |
Cycling 3 Filters: "LBH Long, LBH Short,
& Solar", 2 Frames |
2,LS - 2,LL - 1,SO - 2,S |
4.29 |
|
4-1-2-X |
Cycling 4 Filters: "1304, 1356, LBH Long,
& LBH Short", 2 Frames |
2,04 - 2,56 - 2,LL - 2,LS - 2,S |
6.13 |
|
5-1-2-X |
Cycling All Filters, 2 Frames |
2,04 - 2,56 - 2,LL - 2,LS - 1,SO - 2,S |
6.75 |
|
6-1-8-X |
Fast Mode Fixed Filter: "1304", 8 Frames |
8,04 - 8,04 - 8,04 - 8,04 - 8,04 - 8,S |
7.36 |
|
6-3-8-X |
Fast Mode Fixed Filter: "LBH Short",
8 Frames |
8,LS - 8,LS - 8,LS - 8,LS - 8,LS - 8,S |
7.36 |
|
6-4-8-X |
Fast Mode Fixed Filter: "LBH Long",
8 Frames |
8,LL - 8,LL - 8,LL - 8,LL - 8,LL - 8,S |
7.36 |
|
7-3-1-X |
DB - NM Fixed Filter: "LBH Short" Link
to DB - FM |
2,LS |
1.23 |
|
7-3-2-X |
DB - FM Fixed Filter: "LBH Short" Linked
to DB - NM |
5,LS |
0.76 |
|
7-5-1-X |
DB - NM Fixed Filter: "Solar" Link
to DB - FM |
2,SO |
1.23 |
|
7-5-2-X |
DB - FM Fixed Filter: "Solar" Linked
to DB - NM |
5,SO |
0.76 |
|
8-1-1-X |
Short Duration Test, Cycle All Filters, No Gain |
1,SO - 1,LL - 1,LS - 1,56 - 1,04 - 1,H |
3.68 |
|
9-1-1-X |
HVPS Ramp Down Sequence Steps of 2 From Gain
8 to 0 |
1,S - 1,S - 1,S - 1,S - 1,S - 1,S |
3.68 |
|
9-2-1-X |
HVPS Ramp Up Sequence Steps of 2 to Gain 10 from
0 |
1,S - 1,S - 1,S - 1,S - 1,S - 1,S |
3.68 |
|
10-1-1-X |
Standby Sequence |
1,H |
0.61 |
|
11-1-0-X |
Background Measurement Sequence, Home |
6,H |
3.68 |
|
11-1-6-X |
Background Measurement Sequence, Shutter |
6,S |
3.68 |
|